BASIC INFO
Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers



 



Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers

HIC2031 CURRENT DRIVER, 24 VDC (BUS POWERED), CURRENT OUTPUT UP TO 650, UP TO SIL 2 ACC TO IEC 61508 LOW POWER DISSIPATION.

Manufacturer : Pepperl+Fuchs
Product No : HiC2031
Transmitter Type : SMART Current Driver
Signal type : Analog output
Supply Connection : SL1: 1a(-), 1b(-); 2a(+), 2b(+)
Rated voltage Un : 19 ... 30 V DC via Termination Board
Ripple : = 10 %
Power dissipation : = 600 mW
Power consumption : = 700 mW
Input/Output : safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Ambient temperature : -20 ... 60 °C (-4 ... 140 °F)
Degree of protection : IP20
Mounting on Termination Board
Dimensions : 1.25 x 12.8 x 10.6 cm (0.5 x 5.1 x 4.2 in)



Function of Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers

HiC2031. This isolated barrier is used for intrinsic safety applications. It repeats the input signal from a control system to drive HART I/P converters, valve actuators, and displays located in a hazardous area.
 
 
 
 Ordering Codes of Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers 

HID2025 HID2026 HID2061 HID2061 HID2062 HID2062 HID2071 HID2071 HID2072 HID2072 HID2033 HID2034 HID2031 HID2032 HID2037 HID2038 HID2029 HID2029 HID2030 HID2030 HID2029SK HID2030SK HID2035 HID2036 HID2000 HID2038Y HID2012 HID2038 HID2024 HID2096 HID2025 HID2026 HID2025SK HID2026SK HIC2095 HIC2065 HIC2027 HIC2068 HIC2077 HIC2000 HIC2025ES HIC2031HC HIC2025HC HID2025ES HIC2027DE HID2081 HID2082 H-CJC-SP-8 H-CJC-SC-8 HIC2031 HIC2025 HID2026 HIC2077-Y1 HIC2441 H-CJC-PT100 HIC2025 HIC2031 HIC2027 HIC2027DE HIC2081 HID2025ES HIC2025ES
 

Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers

HiCTB08-YC3-RRB-KS-CC-AM08
Termination Board
System Board for Yokogawa CENTUM VP, For 8-channel AI card AAI135, For 8-channel AI/AO card AAI835, For 8 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB08-YRS-RRB-AK-CC-DI16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel DI card SDV144, For 8 modules, Recommended module: HiC2832R1 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
 
HiCTB08-YRS-RRB-AK-CC-DO08
Termination Board
System Board for Yokogawa ProSafe-RS, For 8-channel DO card SDV531, For 8 modules, Recommended module: HiC2871 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
 
HiCTB08-YRS-RRB-KS-CC-AO08
Termination Board
System Board for Yokogawa ProSafe-RS, For 8-channel AO card SAI533, For 8 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin


Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers
 
HiCTB16-YC3-RRB-AK-CC-DX32
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 16 modules, Recommended module: HiC2822 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
 
HiCTB16-YC3-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB16-YC3-RRB-KS-CC-AI16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAI141, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB16-YC3-RRB-KS-CC-AI16-Y2
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAV141, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin


Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers
 
HiCTB16-YC3-RRB-KS-CC-AM16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAI841, For 16 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB16-YC3-RRB-KS-CC-AM16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAB841, For 16 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB16-YC3-RRB-KS-CC-AO16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AO card AAI543, For 16 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB16-YRS-RRB-AK-CC-DI16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel DI card SDV144, For 16 modules, Recommended modules: HiC2831R1 (DI), HiC2853R1 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
 
HiCTB16-YRS-RRB-AK-CC-DO16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel DO card SDV541, For 16 modules, Recommended modules: HiC2871 (DO), HiC2873 (DO), HiC2877 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers
 
HiCTB16-YRS-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel AI card SAI143, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB16-YRS-RRB-KS-CC-AI16-Y1
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel AI card SAV144, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiCTB32-YC3-RRB-AK-CC-DX32
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 32 modules, Recommended module: HiC2821 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
 
HiCTB32-YC3-RRB-AK-CC-DX32-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DO card ADV551, For 32 modules, Recommended module: HiC2871 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
 
HiDTB08-YC3-RRB-AK-CC-DX32
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 8 modules, Recommended module: HiD2824 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin


Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers
 
HiDTB08-YC3-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), HiD2082 (TI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiDTB08-YC3-RRB-KS-CC-AI16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAV141, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiDTB08-YC3-RRB-KS-CC-AM16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAB841, For 8 modules, Recommended modules: HiD2026 (AI), HiD2038Y (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiDTB08-YC3-RRB-KS-CC-AM16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAI841, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), HiD2032 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
 
HiDTB08-YC3-RRB-KS-CC-AO16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AO card AAI543, For 8 modules, Recommended module: HiD2038Y (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

Pepperl+Fuchs HIC2031 Current Driver HIC2031 Isolated Barriers

We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply 
Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.

 
Why do you choose us?
 
1. 100% original brand product, 100% quality assurance.
    If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send  you a new product asking zero cent.
 
2. Varied payment methods.
    We adopt L/C, D/A, D/P, T/T, and other methods. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
Packaging: Imported with original packaging or standard export packing.Customize design is acceptable.
 
Shipping: By Express(EMS,DHL,UPS,TNT, FEDEX, ARAMEX), By Air, By Sea.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)


Previous:Pepperl+Fuchs HID2062 Temperature Converter HID2062 Isolated Next:P+F KFD2-STC4-Ex2 SMART Transmitter Power Supply KFD2-STC4-E
 Footer begin -->